Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Heat Transfer & Thermodynamics engineering. (36035 members) forum391 - Professional forum and technical support for engineers for Heat Transfer & Thermodynamics engineering. Includes problem solving collaboration tools. Forum.My 1937 copy of Trautwines Civil Engineers Reference Book gives: "Normal reinforcing steel ultimate strength of between 50,000 - 70,000 lbs per sq in with elastic limit (yield) at 25,000 - 35,000 lbs per sq in. Cold working the bars will raise the elastic limit to 40,000 - 50,000 lbs per sq in. Deformed bars have a higher elastic limit claimed ...Actuators are Rotork, valves are a well-known Western manufacturer. One of the actuators is sized at 100% of predicted valve operating torque. To me this instinctively feels incorrect - I made a few calls to friends elsewhere who both suggested actuators are normally capable of 150% - 200% of valve rated torque, …

Eng-Tips Groups Engineering Language/Grammar Skills Engineers with Hobbies Local Exhaust Ventilation NICET Certification, training and education Pats' Pub Translation Assistance for Engineers. People Aeronautics & Space Engineers Activities Aeronautic & Space engineering general discussion Aircraft engineering Rotorcraft engineering …3 May 05 08:35. An estimate of Young's Modulus for concrete is 57,000 (f'c)^2. For cement grout mixes used in augercast piles (usually 3000 psi to 8000 psi), does anyone know of a similar equation to estimate the elasticity? Based on laboratory testing, elasticity of grout is not anywhere near the elasticity of same strength concrete mixes.I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …

1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …

Student Engineer General Discussion. (4380 members) forum1630 - Professional forum and technical support for engineers for Student Engineer General Discussion. Includes problem solving collaboration tools. Forum.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members … Mechanical engineering general discussion. (88334 members) forum404 - Professional forum and technical support for engineers for Mechanical engineering general discussion. Includes problem solving collaboration tools. UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.

Subject: Section VIII-1, UCS-85 (b) and (e) Date Issued: May 31, 1984. File Number: BC82-563. Related Documents: Question (1): A dished head made of P-No. 1 Gr. Nos. 1 and 2 material with a thickness of less than 1¼ in. is hot pressed at a temperature of 1750°F. Are test specimens required under UCS-85 of Section VIII, Division 1, to ...

I'm looking for a code requirement for how much pipe engagement is necessary on a slip-on flange. I know the industry practice is to leave 1/8" -1/4" from the face of the flange to the internal fillet weld, but I need something authoritative in a code or standard to point to.

March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & … Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search. One of the restrictions is to limit the the bead width to 4x core wire diameter. SJones (Petroleum) 3 Jul 08 13:40. Indeed it is: in item (f), 4, a). My apologies for missing this very specific case since it is adopted as the norm for all our vessel and piping SMAW welding. Steve Jones. Materials & Corrosion Engineer.Antenna & propagation engineering. Circuit design. Communication & signal processing engineering. Electric motors & generators engineering. Electric power & transmission & distribution. Electrical Engineering general discussion. Microwave & electromagnetic engineering. Power supply & electronic component design.John Werner. 2023, the writer argues, was the year in which we learned in a theoretical way about how large language models work. 2024, by contrast, is going to be …Structural engineering general discussion. (83014 members) forum507 - Professional forum and technical support for engineers for Structural engineering general discussion. Includes problem solving collaboration tools.InvestorPlace - Stock Market News, Stock Advice & Trading Tips As energy prices continue to climb, it makes sense to look for oil stocks to bu... InvestorPlace - Stock Market N...

Steel Stair Seismic Design. I have posted a couple of threads regarding this subject in the past, but I would like to post a more thourough question regarding providing seismic design on steel stairs. I have a particular project which is in the Missouri area and is governed by the 2006 IBC and ASCE 7-05. I have …Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. 1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …Foundation engineering. (26096 members) forum256 - Professional forum and technical support for engineers for Foundation engineering. Includes problem solving collaboration tools. Forum. Search.Chemical process engineering. (26899 members) forum798 - Professional forum and technical support for engineers for Chemical process engineering. Includes problem solving collaboration tools. Forum.UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.

The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down.

ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.Men's Health offers eighteen tricks that make a body feel better, like how to clear a stuffed nose or make an injection hurt less. Men's Health offers eighteen tricks that make a b...While specific laws vary by state, the general process of assessing real property is similar across the country. If you own real estate, it will be assessed, and that assessment w...forum337 - Professional forum and technical support for engineers for Wood design and engineering. Includes problem solving collaboration tools. Search.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register … Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search. 22 hours ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ...

Update: My final solution was to drill and epoxy #3 bars at 24" OC (every 3 CMU courses) with 18" of embedment into the existing walls. However, there was an ice storm in late December that revealed more structural problems with the building only to be exacerbated by the winter storm from February.

Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net Joined March 2009. 124 Following. 295 Followers. Tweets & replies. Media.

Electric power & transmission & distribution. (59316 members) forum238 - Professional forum and technical support for engineers for Electric power & transmission & …Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …As we lose the stable structure we’re used to, many of us are now experiencing symptoms of burnout. How can we overcome it? Humans are creatures of habit. We function best and feel...The following are some parameters that affect how pinned versus fixed a base plate is. Plate thickness-Really thin plates resist very little rotation whereas thicker plates do aid in resisting rotation. Thin plates flex. Anchor Bolt Location-Bolts close to the center of your section tend to act more pinned. Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines. PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book.Foundation engineering. (26096 members) forum256 - Professional forum and technical support for engineers for Foundation engineering. Includes problem solving collaboration tools. Forum. Search. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. Water treatment & distribution. (21029 members) forum164 - Professional forum and technical support for engineers for Water treatment & distribution. Includes problem solving collaboration tools. Forum. Student Engineer General Discussion. (4380 members) forum1630 - Professional forum and technical support for engineers for Student Engineer General Discussion. Includes problem solving collaboration tools. Forum.Eng-Tips Groups Engineering Language/Grammar Skills Engineers with Hobbies Local Exhaust Ventilation NICET Certification, training and education Pats' Pub Translation Assistance for Engineers. People Aeronautics & Space Engineers Activities Aeronautic & Space engineering general discussion Aircraft engineering Rotorcraft engineering …woman with red coat walking up the stairs to the clouded sky Cancer Matters Perspectives from those who live it every day. Your email address will not be published. Required fields...

hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.The nosing provides clearance space for your heel to drop on the tread. If there were no nosing, your heel might hit the riser and you will stumble forward (and probably fall if you are not holding n the handrail). msquared48 (Structural) 20 Apr 09 19:27. To encourage tripping as you go up the stairs.MotorCity (Structural) 16 Sep 04 09:48. KarlIt, I would suggest consulting the goal manufacturer to obtain the design loads. The support system will vary among models and manufacturers. This type of loading is not governed by any particular code as it is not a building or structure. That has been my approach for the gymnasium designs in the ...Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Instagram:https://instagram. hello kitty lettuce plushmylumenups store nyc hoursabc 12 flint mi Cut Weight for Ring Forgings... thread794-517252. MVPs. ring forgings (Mechanical) (OP) 12 Mar 24 16:20. Hello all, espn nfl fpithe cardigan taylor swift SIG:Please see FAQ731-376: Eng-Tips.com Forum Policies for tips on how to make the best use of Eng-Tips. RE: "Break sharp edges" note. berkshire (Aeronautics) 26 Feb 09 19:32. The most common tool for breaking sharp edges in the aircraft industry is a small tool called a Burr Wik, it has a receptacle into which several types of scraper like …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search … some other woman showtimes near regal ua cottonwood Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search. InvestorPlace - Stock Market News, Stock Advice & Trading Tips As energy prices continue to climb, it makes sense to look for oil stocks to bu... InvestorPlace - Stock Market N...